MicroCATH
Flow Direct Catheter
MicroCATHⓇ Catheter is a Neurovascular intervention that uses minimally-invasive endovascular techniques to treat vascular diseases of the brain. Physicians who perform these procedures receive highly specialized training in interventional neuroradiology and/or endovascular neurosurgery.
Usable Length | 90 cm, 150 cm | |
Tip Length | 1.5 cm, 3 cm | |
Tip Shape | Straight tip | |
Catheter Profile Proximal | 2.1F, 2.7F | |
Catheter Inner Diameter | 1.3F, 1.5F | |
Radiopaque Marker | 1 mm located at 2 mm from the tip | |
Guidewire Compatibility | Maximum diameter 0.012" | |
Coating | Hydrophilic | |
Minimum Dead Space | 0.2 ml | |
Structure of the Catheter | PE/PEBAX |
Invamed MicroCath Catheter products are Medical-Surgical products (which can be used inside the body in surgeries) with the qualifications required by MEDDEV 2.7.1 and the “EU Directive” numbered 93/42/EEC. There are different types according to different usage areas and diameters. It is suitable for the use of 0.014” micro guide wire and is supplied together. The tip has a radiopaque marker and is highly visible under ultrasound. 5F, 6F, and 7F diameter; It has 90 cm and 150 cm lengths and is compatible with embolizing agents. DMSO compatible. It has an internal diameter of 0.028 in (0.7 mm/0.6 mm/0.5 mm) flowing minimally in the distal regions. The microcatheter lumen can be contained within steerable guidewires 0.018 in (0.47 mm) in diameter or less. Embolizing agent is compatible.
![MicroCATH Flow Direct Catheter-1](https://invamedurology.com/img/product/190-1628431520.webp)
![Product Image](https://invamedurology.com/img/product/190-1628431520.webp)
Detailed specifications
We offer advanced solutions for the treatments of the following brain diseases:
- Intracerebral AVMs and AV Fistulas
- Intracerebral aneurysms
- Inntracranial stenosis
- Ischemic stroke and intracerebral thrombus
- Tumors
MicroCATHⓇCatheter is the Flow dependent microcatheter with a strong resistance to pressure and total DMSO compatibility.
The catheters are the only real flow-dependent catheters, meaning that their progression through the arteries system is facilitated by the blood flow. This characteristic is achieved thanks to an extreme suppleness of the tubes which allows a fast and non-traumatic progression of the catheter inside the blood vessels.
Detectable-part
Compatible embolizing agents:
- NBCA
- ethanol
- lipiodol
- microspheres
- PVA Particles
- Chemoembolization Agents
- Contrast media
The use of the MicroCATHⓇ detachable-tip microcatheter for embolization of AVMs and AVFs is associated with high rates of successful catheterization and obliteration and low rates of morbidity and mortality.
- Hydrophilic coating
- Excellent kink resistance and pushability
- Dedicated tip design with radiopaque marker
- Excellent crossability
- Ensures reliable fluoroscopic visibility
- Choice of different catheter sizes ( 2.1 Fr and 2.7 Fr, guide catheter compatibility)
- Optimized tip design
- High compressive strength
- Low profile
- DMSO compatibility
- Embolizing agent compliance
- Flow Directed
- Detachable Tip structure
- Over the guidewire (0.012”) system avoiding vessel wall damage.
Usable Length | 90 cm, 150 cm | |
Tip Length | 1.5 cm, 3 cm | |
Tip Shape | Straight tip | |
Catheter Profile Proximal | 2.1F, 2.7F | |
Catheter Inner Diameter | 1.3F, 1.5F | |
Radiopaque Marker | 1 mm located at 2 mm from the tip | |
Guidewire Compatibility | Maximum diameter 0.012" | |
Coating | Hydrophilic | |
Minimum Dead Space | 0.2 ml | |
Structure of the Catheter | PE/PEBAX |
Order Number | Proximal Outer Diameter | Inner Diameter | Distal Outer Diameter | Usable Lenght | Max Guidewire compatibility | Distal Tip Lenght |
VS1168 | 2.7 Fr | I.D. ≥ 0.013" / 0.33 mm | 1.5 / 0.020” | 90 cm | 0,010” | 3 cm |
VS1169 | 2.7 Fr | I.D. ≥ 0.013" / 0.33 mm | 1.5 / 0.020” | 150 cm | 0,010” | 1.5 cm |