Keeper
Retriever Endovascular Snare Looped Designed
KeeperⓇ Retrieval Technology is your first choice safety device when it comes to successful retrieval.
Keeper Retrieval Technology is your first choice safety device when it comes to successful retrieval
Especially designed to meet the high requirements during extraction. Interlaced Nitinol Loops designed to resist prolapse and imrpove capture by allowing the snare to mave as a single-unit through the vessel.
The Invamed Snare Set includes three super elastic nitinol rim basket tools. It is a flexible catch loop for removing foreign substances from veins or body cavities. Snare consists of super flexible nitinol wires with a special loop structure. Due to the very special properties of nitinol, the loop structure returns to its original form after leaving the introducer sheath. Snare should only be used by physicians experienced in interventional techniques, with a matching introducer sheath.
Detailed specifications
Specially designed to meet the high requirements during extraction
Interlaced Nitinol Loops are designed to resist prolapse and improve capture by allowing the snare to move as a single unit through the vessel.
Embedded Radiopaque Marker Band identifies the snare delivery catheter’s precise location under imaging.
Improved Vessel Navigation facilitated by a 15-degree curved tip on 4F, 6F, and 7F snare delivery catheters.
High-Performance Snare Delivery Catheter designed for strength and to minimize the potential for kinking and buckling.
Enhanced Visualization provided by platinum strands incorporated into the loops
The high degree of vessel coverage within a wide range of vessel sizes 5mm to 35mm and is available in lengths of 120 cm. With extra high pulling forces of up to 5.5kg.
Have been specially designed to meet the high requirements during extraction.
KeeperⓇRetrieval Technology is your first choice safety device when it comes to successful retrieval.
KeeperⓇretrieval device allows simplified retrieval of foreign bodies like lost catheters, guidewires , stents, as well as coil manipulation Vena Cava Filter retrieval in small to extra large vessels.
The high upstanding force plus a 1:1 torque and loop diameters ranging from 5 to 35 mm together with a pre-shaped and shapeable delivery sheath catheter of 4, 6, and 7F makes it the emergency device of choice.
FOR LARGE VESSELS
Diameter 5, 10, 15, 20, 25, 30, 35
Vessels 3-5 mm, 6-10mm, 11-15mm, 16-20mm,25mm, 26-30mm, 31-35mm
Lenght 135
Introducer Sheath 6F,7F
Catheter 120 cm
Guidewire Compatibility 0.035”
FOR SMALL VESSELS
Diameter 2, 4, 7, 20, 25, 30, 35
Vessel 1-2 mm, 3-4mm, 5-7mm
Lenght 135
Introducer Sheath 4F
Catheter 120 cm
Guidewire Compatibility 0.018”
KeeperⓇRetrieval Technology is your first choice safety device when it comes to successful retrieval.
Specially designed to meet the high requirements during extraction.
Interlaced Nitinol Loops are designed to resist prolapse and improve capture by allowing the snare to have as a single unit through the vessel.
KeeperⓇRetrieval Technology is your first choice safety device when it comes to successful retrieval.
Especially designed to meet the high requirements during extraction.
Interlaced Nitinol Loops designed to resist prolapse and imrpove capture by allowing the snare to mave as a single-unit through the vessel.
Order Number | Diameter | Working Length | Catheter Lenght |
VS1081 | 4 Fr | 135 cm | 120 cm |
VS1082 | 6 Fr | 135 cm | 120 cm |
VS1083 | 7 Fr | 135 cm | 120 cm |