Keeper
Retriever Endovascular Snare Looped Designed

Keeper Retrieval Technology is your first choice safety device when it comes to successful retrieval.


Share

Keeper Retrieval Technology is your first choice safety device when it comes to successful retrieval

Especially designed to meet the high requirements during extraction. Interlaced Nitinol Loops designed to resist prolapse and imrpove capture by allowing the snare to mave as a single-unit through the vessel.

The Invamed Snare Set includes three super elastic nitinol rim basket tools. It is a flexible catch loop for removing foreign substances from veins or body cavities. Snare consists of super flexible nitinol wires with a special loop structure. Due to the very special properties of nitinol, the loop structure returns to its original form after leaving the introducer sheath. Snare should only be used by physicians experienced in interventional techniques, with a matching introducer sheath.

Detailed specifications

Specially designed to meet the high requirements during extraction

Interlaced Nitinol Loops are designed to resist prolapse and improve capture by allowing the snare to move as a single unit through the vessel.

Embedded Radiopaque Marker Band identifies the snare delivery catheter’s precise location under imaging.

Improved Vessel Navigation facilitated by a 15-degree curved tip on 4F, 6F, and 7F snare delivery catheters.

High-Performance Snare Delivery Catheter designed for strength and to minimize the potential for kinking and buckling.

Enhanced Visualization provided by platinum strands incorporated into the loops

The high degree of vessel coverage within a wide range of vessel sizes 5mm to 35mm and is available in lengths of 120 cm. With extra high pulling forces of up to 5.5kg.

Have been specially designed to meet the high requirements during extraction.

KeeperRetrieval Technology is your first choice safety device when it comes to successful retrieval.

Keeperretrieval device allows simplified retrieval of foreign bodies like lost catheters, guidewires , stents, as well as coil manipulation Vena Cava Filter retrieval in small to extra large vessels.

The high upstanding force plus a 1:1 torque and loop diameters ranging from 5 to 35 mm together with a pre-shaped and shapeable delivery sheath catheter of 4, 6, and 7F makes it the emergency device of choice.

FOR LARGE VESSELS

Diameter                                            5, 10, 15, 20, 25, 30, 35

Vessels                                               3-5 mm, 6-10mm, 11-15mm, 16-20mm,25mm, 26-30mm, 31-35mm

Lenght                                                135

Introducer Sheath                              6F,7F

Catheter                                             120 cm

Guidewire Compatibility                    0.035”

FOR SMALL VESSELS

Diameter                                            2, 4, 7, 20, 25, 30, 35

Vessel                                                 1-2 mm, 3-4mm, 5-7mm

Lenght                                                135

Introducer Sheath                              4F

Catheter                                             120 cm

Guidewire Compatibility                    0.018”

KeeperRetrieval Technology is your first choice safety device when it comes to successful retrieval.

Specially designed to meet the high requirements during extraction.

Interlaced Nitinol Loops are designed to resist prolapse and improve capture by allowing the snare to have as a single unit through the vessel.

KeeperRetrieval Technology is your first choice safety device when it comes to successful retrieval.
Especially designed to meet the high requirements during extraction.
Interlaced Nitinol Loops designed to resist prolapse and imrpove capture by allowing the snare to mave as a single-unit through the vessel.

Order Number Diameter Working Length Catheter Lenght
VS1081 4 Fr 135 cm 120 cm
VS1082 6 Fr 135 cm 120 cm
VS1083 7 Fr 135 cm 120 cm