Dovi
Thrombo Aspiration System
Dovi is an innovative aspiration catheter designed to offer a balance between crossing performance, kink resistance, and thrombus-aspiration capability.
Dominate Thrombus Management Adjustable Aspiration Jet Speed
- Antiblactics
- Antibiotics
- Thrombolytics
- Antithrombics
- Vasodilators
- Constrast agents
Dovi Thromboaspiration System is a thromboaspiration system used in coronary vessels, and peripheral arteries/veins. The system works unidirectionally, both opening the vessel lumen and preventing the distal migration of the thrombus material. The Dovi Thromboaspiration System intervenes in the thrombus and the thrombus in the vein is actively and rapidly cleared separately from the blood. The “Dovi Thromboaspiration System” is for single use only.
Detailed specifications
ASPIRATION CATHETER
- Optimized tip design
- Strong washability and superior fracture resistance
- Large extraction lumens that provide better aspiration
- Prevents vascular wall damage through the guide wire system
- The side aspiration window allows efficient aspiration of the thrombus adhered to the wall
- The catheter is designed and proven to dissolve small, fresh thrombi in peripheral vessels.
Indicated Vessels
- Peripheral Veins
- Pulmonary Artery
- Inferior Vena Cava
- Subclavian Vein
- Hepatic Vein
CLINICAL SUCCESS
Common iliac, external iliac, common femoral, femoral, and popliteal veins of the lower extremities deep vein thrombosis (DVT)’s treatment of 80 patients, by Percutaneous Thrombectomy between the dates of September 2020 and October 2019 (MO) underwent therapy. Aspiration and mechanical thrombectomy procedures were performed until the thrombus was completely dissolved using the Dovi Aspiration system and the Mantis Mechanical Thrombectomy System for thrombectomy (Invamed, Ankara, Turkey).
AS A RESULT OF THE STUDY, 95% of SUCCESSFUL RESULTS WERE OBTAINED IN THE TREATMENT of deep vein thrombosis (DVT) of the lower extremities of the iliac, external iliac, common femoral, femoral and popliteal veins.
- Hydrophilic coating
- Excellent bending resistance and repellency
- Enhanced power, torque, and flexural resistance
- Easy navigation between curvy decides
- Special tip design with radioopaque marker
- Excellent crossability while providing atraumatic and effective aspiration
- Provides reliable fluoroscopic visibility
- Large Extraction Area
- Continuous, high-performance aspiration throughout the procedure
- Selection of different catheter sizes (5 Fr, 6 Fr, 7 Fr, and 8Fr guide catheter compatibility) for different coronary and peripheral applications.
Voltage | 100-240 VAC | |
Frequency | 50Hz - 60Hz | |
Current | 2.0 A | |
Fuse | Two 2 A, 5 X 20 mm, Start-up Speed Type T(Time-delay fuse) | |
Cut-off Capacity | Cutting Capacity 1500 A; at 250 VAC (T2A H 250VAC) | |
Port Output | 5-20 VDC, 3.0 A | |
Motor and Pump Description | Oil-free, diaphragm pump | |
Vacuum Range | 80 - 550 mmHg | |
Output power | 0 - 27 /min | |
Dimensions | 18 x 23 x 20 cm | |
Weight | 1.7kg (not including AC-DC adapter) | |
Battery Capacity | 60 min | |
Disposable Collection Container Capacity | 800ml(cc) |
Order Number | Device outer diameter | Working Length |
VS1050 | 6.0 Fr | 90 cm |
VS1045 | 6.0 Fr | 100 cm |
VS1046 | 6.0 Fr | 110 cm |
VS1047 | 6.0 Fr | 115 cm |
VS1048 | 6.0 Fr | 120 cm |
VS1049 | 6.0 Fr | 125 cm |
VS1050 | 6.0 Fr | 135 cm |
VS1051 | 8.0 Fr | 90 cm |
VS1052 | 8.0 Fr | 95 cm |
VS1053 | 8.0 Fr | 100 cm |
VS1054 | 8.0 Fr | 110 cm |