Inca
Trellis Thrombolysis System
INCA PROTECTION SYSTEM DEVELOPED FOR ACUTE APPLICATION OF SYSTEMIC THROMBOLYSIS. INCA Trellis is designed to perform as a Thrombolysis system. INCA’s easy placement system is suitable for acute PE, VTE, ICU, thrombectomy, and prophylactic patients. Permanent Solution to Acute Venous Thrombosis
Invamed INCA Thrombolysis System is a Medical-Surgical product with the qualifications required by the "EU Directive" numbered 93/42 / EEC (can be used in the body during surgery). diagnostic and/or therapeutic agents and controlling blood flow to the selected area in patients with peripheral thrombus and at risk of pulmonary embolism. There are fibrinolytic and thrombolytic drug delivery ports. In this way, systemic thrombolysis activities can be performed from here. It is compatible with a 0.035 ”guide wire. Nitinol protective cage-shaped filter system is located in the most distal part of the device. Acting as a protective filter system provides additional protection for the patient against . After the process is complete There are 14 micropores with a diameter of 0.2 mm located at an angle of 180 degrees in a 14.4 cm section from the distal of the device. Infusion of thrombolytic agents occurs from these micropores.
Detailed specifications
In the presence of acute deep venous thrombosis involving inferior vena cava or iliofemoral vein segments and without recanalization
It can be used for injecting diagnostic and/or therapeutic agents and controlling blood flow to the selected area in patients with acute deep venous thrombosis involving the inferior vena cava or iliofemoral vein segments and without recanalization, peripheral thrombus patients, and patients at risk for pulmonary embolism. There are fibrinolytic and thrombolytic drug delivery ports. In this way, systemic thrombolysis activities can be performed from here.
IncaⓇ Trellis is engaged in the design, development, manufacture, and distribution of innovative endovascular catheters used in interventional procedures, particularly in catheter-guided thrombolysis (CDT) of large thrombi, in patients affected by arterial and venous thromboembolic conditions.
IncaⓇ Trellis offers an innovative line of endovascular catheters with a unique combination of pharmacomechanical, expandable shielding filters for the effective treatment of arterial and venous thromboembolic conditions, especially when treating large thrombi.
This unique approach provides additional protection along with thrombolytic therapy.
The Thrombectomy System features laser-punched custom gradient hole sizes in a spiral pattern for a more homogeneous distribution of therapeutic agents in slow continuous infusion with multiple application options.
There is a model with a filter mechanism that acts as a protective shield against the risk of embolism during the lysis process, and a wire model with a special design to prevent clogging. Both systems have 360-degree lysis processing ports. It is used with the device that provides an infusion of fibrinolytic drugs at different pressures at different power settings.
- Antiblastics
- Antibiotics
- Thrombolytics
- Antithrombotics
- Vasodilators contrast agents
SCIENTIFIC ARTICLES
It performs fibrinolytic therapy with high contact of the thrombolytic agent with the thrombus surface.
Immediate PE protection
- 100% Retrievable
- Self – Centering
- Innovative Design
- No risk Migration
- Maintains shape and positioning: Outstanding durability, even in the longest procedures
- Stainless steel coil structure for consistent reliability
- Allows easy penetration and smooth transition.
- Smooth transitions: dilator-to sheath to Filter shaft
- Provides lesion access: Exceptional trackability, even in the most challenging anatomy
- Enhances visualization for precise positioning
- Provides smooth movement: Coil reinforced tubing and PTFE inner-layer that minimizes friction
- Shapes and sizes to meet your peripheral challenges
Design | Sinusoidal wawe shape | |
Infusion zone | 10 cm from distal tip | |
Catheter Lenght | 30cm, 45cm, 90cm, 110cm | |
Catheter Profile | 5F - 7.0F | |
Radiopacity | Braided Catheter is visible from the distal tip to proximal shaft | |
Active Zone | 15 cm | |
Catheter Inner Layer | PTFE | |
Structure of the Catheter | Nitinol shape PE/PEBAX |
Order Number | Filter outer diameter | Working Length | Catheter Diameter |
VS1057 | 32 cm | 30 cm | 8.0 Fr |
VS1058 | 32 cm | 30 cm | 9.0 Fr |
VS1059 | 32 cm | 30 cm | 10.0 Fr |
VS1060 | 32 cm | 40 cm | 8.0 Fr |
VS1061 | 32 cm | 40 cm | 9.0 Fr |
VS1062 | 32 cm | 40 cm | 10.0 Fr |
VS1063 | 32 cm | 50 cm | 8.0 Fr |
VS1064 | 32 cm | 50 cm | 9.0 Fr |
VS1065 | 32 cm | 50 cm | 10.0 Fr |